R-FFS-K-A4 Frame fixing with the shortest anchoring zone and collar hex head - stainless steel

Universal frame fixing with collar and hex head screw for many applications

Features and benefits

  • Shortest anchoring depth - only 40/50 mm
  • Frame fixing made of A4 steel intended for outdoor use
  • Quick assembly thanks to the short anchoring zone and the possibility of using a punch-tool in aerated concrete
  • Specially-formulated nylon allows best performance installation for use in all base material categories according to ETAG 020 (A, B, C, D)
  • Internal plug geometry designed to fit the screw head
  • Plug design ensures multi-axis expansion
  • Collared plug for fixing of hard materials (eg. steel)

Product information

Size

Product Code

Plug

Screw

Fixture

Screw drive

Diameter

Length

Diameter

Length

Hole diameter

d

l

d1

L1

df

[mm]

[mm]

[mm]

[mm]

[mm]

-

Ø10

R-FFS-N-10K050-A4

10

50

7

59

12,5

T40

R-FFS-N-10K060-A4

10

60

7

69

12,5

T40

R-FFS-N-10K080-A4

10

80

7

89

12,5

T40

R-FFS-N-10K100-A4

10

100

7

109

12,5

T40

R-FFS-N-10K120-A4

10

120

7

129

12,5

T40

Base material

  • Concrete ≥ C12/15 (Use category A)

    Concrete ≥ C12/15 (Use category A)

  • Solid Brick (Use category B)

    Solid Brick (Use category B)

  • Solid Sand-lime Brick (Use category B)

    Solid Sand-lime Brick (Use category B)

  • Hollow Brick (Use category C)

    Hollow Brick (Use category C)

  • Hollow Sand-lime Brick (Use category C)

    Hollow Sand-lime Brick (Use category C)

  • Hollow Lightweight Concrete Block (Use category D)

    Hollow Lightweight Concrete Block (Use category D)

  • Aerated Concrete Block (Use category D)

    Aerated Concrete Block (Use category D)

  • Cracked concrete ≥ C12/15 (Use category A)

    Cracked concrete ≥ C12/15 (Use category A)

Applications

  • Ventilated facades
  • Door and window frames
  • Garage doors
  • Gates
  • Industrial doors
  • Facade (substructures made of wood and metal)
  • Wall cabinets
  • Satelite dishes
  • Shelves
  • Handrails
  • Cable trays

Installation guide

Installation guide
Installation guide
Installation guide
Installation guide
Installation guide
Installation guide
  1. Drill a hole of required diameter and depth (figure 1 - base material A,B,C,D) or use punch-tool in aerated concrete (figure 2 - base material D)
  2. With a hammer, lightly tap the plug through the fixture into hole until fixing depth is reached
  3. Tighten the R-FFS screw

Installation data

Size

Ø10

Ø10

Hole diameter in substrate

d0

[mm]

10

10

Min. hole depth in substrate

h0

[mm]

50

60

Min. installation depth

hnom

[mm]

40

50

Min. substrate thickness

hmin

[mm]

100

100

Min. spacing

smin

[mm]

70

80

Min. edge distance

cmin

[mm]

50

70

Head size

sw

[mm]

13

13

Screw drive

-

[-]

T40

T40

Effective embedment depth

hef

[mm]

40

50

Associated products

  • RT-SDSA Drill bits Aggressor SDS plus

    RT-SDSA Drill bits Aggressor SDS plus

  • RT-SDSB Drill bits Brickdrill SDS plus

    RT-SDSB Drill bits Brickdrill SDS plus

  • RT-SDSR Drill bits Rebardrill SDS plus

    RT-SDSR Drill bits Rebardrill SDS plus

  • ce
  • iso 9001
  • ISO 4001
  • isots16949
  • ohsas 18001
  • tuv